ReviewBuilding
Review Date06/07/2017
StatusApproved
Comments
Sheet I-1103 DOOR SCHEDULE AND TYPE: NOT RESOLVED:
Provide evidence that the Concealed Rod panic Device installed on each of the exterior exit doors comply with Section 1008.1.10 of the VCC 2012 which requires:
1- Panic hardware be listed with UL 305.
2- The actuating portion of the releasing device shall extend at least one-half of the door leaf.
3- The maximum unlatching force shall not exceed 15 pounds (67 N).
  



  
 